back to overview

SALT SPRAY TEST

The tests with a 5% NaCl water solution are carried out either at a constant temperature (35 °C) or at varying temperatures from -40 °C to + 80 °C. Therefore, the Turnkey salt spray test chambers are available either in stainless steel or GKV design. In both versions, the corrosion resistance test of the lithium-ion batteries is carried out according to GS 95024-3-1 section K06 and K07 and DIN EN 60068-2-11.

Use Case
3
Watch impressions