weisstechnik units available from stock.
Request today – start testing next week*.
As a company operating globally, weisstechnik has an extensive pool of devices on stock and for rent. This includes temperature and climate test chambers as well as stability, corrosion and temperature shock test chambers. Take a look – your next test chamber is only a few clicks away.
Nr. | Application | Type of unit | Equipment | Test space volume [l] |
Min. Temperature [°C] |
Temperature change rate [K/min] |
Year of construction | |
---|---|---|---|---|---|---|---|---|
1 | Temperature | VT 4021-M | 64845907 Door with Window 64844917 Temp Mesurement on test specimen 58566232150040 refrigerant conversion |
210 | -40 | 3 | 2017 | |
2 | Climate | ClimeEvent C/180/70/5 | 64624915 Door with window 64609904 Mobile design 64624936 Temp mesurement on test specimen |
180 | -70 | 5 | 2017 | |
3 | Climate | VCL 4006 | 64592024 Water-cooled version 64592017 8 color touch panel 64592031 Access Port Ø 80 mm, L1 64592085 Mobile version for 64 |
64 | -40 | 3 | 2018 | |
4 | Climate | ClimeEvent C/600/70/3 | 64624915 Door with window 64611904 mobile design |
600 | -70 | 3 | 2019 | |
5 | Climate | ClimeEvent C/1500/70a/5 | Door with window mobile design |
1500 | -70 | 5 | 2020 | |
6 | Corrosion | SaltEvent SC/KWT 500 | - | 500 | 0 | 3 | 2020 | |
7 | Temperature | TempEvent T/600/40/5/S (LI-Ion) | 64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5 |
600 | -40 | 5 | 2020 | |
8 | Temperature | TempEvent T/600/40/5/S (LI-Ion) | 64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5 |
600 | -40 | 5 | 2020 | |
9 | Temperature | TempEvent T/1000/40/5/S (LI-Ion) | 64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5 |
1000 | -40 | 5 | 2020 | |
10 | Temperature | TempEvent T/1000/40/5/S (LI-Ion) | 64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5 |
1000 | -40 | 5 | 2020 | |
11 | Shock | ShockEvent T/60/V2 | - | 60 | -80 | ShockEvent | 2020 | |
12 | Shock | ShockEvent T/60/V2 | - | 60 | -80 | ShockEvent | 2020 | |
13 | Shock | ShockEvent T/60/V2 | - | 60 | -80 | ShockEvent | 2020 | |
14 | Shock | ShockEvent T/60/V2 | - | 60 | -80 | ShockEvent | 2020 | |
15 | Climate | ClimeEvent C/600/40/3 | 64612904 mobile design 64624915 Door with window |
600 | -40 | 3 | 2020 | |
16 | Climate | ClimeEvent C/600/70a/5 | 64611904 mobilde desgin 64624915 Door with window |
600 | -70 | 5 | 2020 | |
17 | Climate | C 340,-70 | 0 | 340 | -70 | 3 | 2019 | |
18 | Corrosion | SaltEvent SC 1000 | - | 1000 | 0 | SaltEvent | 2021 | |
19 | Shock | ShockEvent T/120/V2 | - | 120 | -80 | ShockEvent | 2018 | |
20 | Temperatur | TempEvent T/1000/70/3/M | 4627913 Test space lighting, 2 x 50 W, 24 V 64624915 Window in the door 64610930 Disconnection of fan via digital channel 64624930 Temperature measurement on test specimen 64631932 Analogue measuring data card 4x input, 5x output 64645927 Air-cooled condenser, at a distance of approx. 3 m (heat dissipation passed to external condenser) 64568927 Refrigerant line, 2-fold, extension to a total distance of 3 m |
1000 | -70 | 3 | 2019 | |
21 | Stability | PharmaEvent Stabilitätsprüfcontainer 40' | - | 47m³ | 0 | PharmaEvent | 2020 | |
22 | Stability | PharmaEvent Stabilitätsprüfcontainer 20' | - | 18m³ | 0 | PharmaEvent | 2020 | |
23 | Temperatur | LabEvent T/40/70/5 | 64843403 Door with window | 40 | -70 | 5 | 2020 | |
24 | Climate | ClimeEvent C/600/70a/3 | 64624915 Window in the door 64611904 Mobile design |
600 | -70 | 3 | 2020 | |
25 | Temperature | LabEvent T/40/70/5 | 64843403 Door with window | 40 | -70 | 5 | 2021 | |
26 | Temperature | LabEvent T/210/70/5 | 64845907 Door with window | 210 | -70 | 5 | 2021 | |
27 | Climate | ClimeEvent C/600/70a/5 | 64611904 mobilde desgin 64624915 Door with window |
600 | -70 | 5 | 2021 | |
28 | Temperature | LabEvent T/210/70/5 | 64845907 Door with window | 210 | -70 | 5 | 2021 | |
29 | Climate | ClimeEvent C/340/70a/5 | 64624915 Door with window 64609904 mobile design |
340 | -70 | 5 | 2021 | |
30 | Temperatur | LabEvent T/40/70/5 | 64843403 Door with window | 40 | -70 | 5 | 2021 | |
31 | Climate | ClimeEvent C/1000/70a/5 | 64612904 mobile design 64624915 Door with window |
1000 | -70 | 5 | 2021 | |
32 | Schock | ShockEvent T/120/V2 | - | 120 | -80 | ShockEvent | 2021 |
*Subject to prior sale. While stock last.