weisstechnik units available from stock.
Request today – start testing next week*.
As a company operating globally, weisstechnik has an extensive pool of devices on stock and for rent. This includes temperature and climate test chambers as well as stability, corrosion and temperature shock test chambers. Take a look – your next test chamber is only a few clicks away.
Nr. | Application | Type of unit | Test space volume [l] |
Min. Temperature [°C] |
Temperature change rate [K/min] |
Year of construction | Serial number | |
---|---|---|---|---|---|---|---|---|
1 | Temperature | VT 4021-M "64845907 Door with Window 64844917 Temp Mesurement on test specimen 58566232150040 refrigerant conversion" |
210 | -40 | 3 | 2017 | 58566232150010 | |
2 | Climate | WK8/40-85 (ehemals CentroTherm ) "Delivery time according to technical Clarification about 23 weeks" | 8000 | -40 | 3 | 0 | 59222482290010 | |
3 | Climate | VCL 4006 "64592024 Water-cooled version 64592017 8 ""color touch panel 64592031 Access Port Ø 80 mm, L1 64592085 Mobile version for 64" |
64 | -40 | 3 | 2018 | 56546015690010 | |
4 | Climate | ClimeEvent C/600/70/3 "64624915 Door with window 64611904 mobile design" |
600 | -70 | 3 | 2019 | "6319275 10000000000272" | |
5 | Climate | ClimeEvent C/1500/70a/5 "Door with window mobile design" | 1500 | -70 | 5 | 2020 | 58566262440010 | |
6 | Shock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2020 | "6328900 10000000000823" | |
7 | Climate | ClimeEvent C/1000/70/3 "64624915 Door with window 64612904 Mobile design" |
1000 | -70 | 3 | 2020 | 6331442 | |
8 | Climate | ClimeEvent C/1500/70a/5 "64612904 mobilde desgin 64624915 Door with window" |
1500 | -70 | 5 | 2020 | 58226220730010 | |
9 | Shock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2020 | "6331412 10000000000326" | |
10 | Temperature | TempEvent T/340/70/5 - | 340 | -70 | 5 | 2018 | 58566243740010 | |
11 | Temperature | TempEvent T/600/40/5/S (LI-Ion) "64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5" |
600 | -40 | 5 | 2020 | 58566265400010 | |
12 | Temperature | TempEvent T/600/40/5/S (LI-Ion) "64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5" |
600 | -40 | 5 | 2020 | 58226224370010 | |
13 | Temperature | TempEvent T/1000/40/5/S (LI-Ion) "64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5" |
1000 | -40 | 5 | 2020 | 58226224380010 | |
14 | Temperature | TempEvent T/1000/40/5/S (LI-Ion) "64624915 Door with Window 64612904 Mobile Design 64625923 Access port Ø 125 mm (L2, R2) 64626942 Safety package for EUCAR hazard level 4 58566265400060 Preparation for Hazard Level 5" |
1000 | -40 | 5 | 2020 | 58566266440010 | |
15 | Shock | ShockEvent T/60/V2 - | 60 | -80 | ShockEvent | 2020 | 6345842 | |
16 | Shock | ShockEvent T/60/V2 - | 60 | -80 | ShockEvent | 2020 | 6345841 | |
17 | Climate | ClimeEvent C/600/40/3 "64612904 mobile design 64624915 Door with window" |
600 | -40 | 3 | 2020 | 6348330 | |
18 | Climate | ClimeEvent C/1000/70a/3 "64612904 mobile design 64624915 Door with window" |
1000 | -70 | 3 | 2020 | 6343685 | |
19 | Climate | ClimeEvent C/1000/70a/5 "64612904 mobile design 64624915 Door with window" |
1000 | -70 | 5 | 2020 | 6348843 | |
20 | Climate | ClimeEvent C/1000/70a/5 "64612904 mobile design 64624915 Door with window" |
1000 | -70 | 5 | 2020 | 6348844 | |
21 | Climate | C 1000,-40 0 | 1000 | -40 | 3 | 2020 | 54260026820150 | |
22 | Temperatur | TempEvent T/1000/70/3/M "4627913 Test space lighting, 2 x 50 W, 24 V 64624915 Window in the door 64610930 Disconnection of fan via digital channel 64624930 Temperature measurement on test specimen 64631932 Analogue measuring data card 4x input, 5x output 64645927 Air-cooled condenser, at a distance of approx. 3 m (heat dissipation passed to external condenser) 64568927 Refrigerant line, 2-fold, extension to a total distance of 3 m" |
1000 | -70 | 3 | 2019 | 58226210290010 | |
23 | Stability | PharmaEvent Stabilitätsprüfcontainer 40' - | 47m³ | 0 | PharmaEvent | 2020 | 59436025090010 | |
24 | 0 | SC 340 MHG "64610735 Isolation cover for opening 64610945 Controlling of black standard temperature 64241159 Measuring card for 4 Pt 100 inputs and 5 analogue outputs for set point and actual values 59222201880001 Test room door with observation window 450 x 600 mm, incl. test room lighting and external Flap lid to close the window at activated irradiation device 59222201880002 Connection cable 3 m for demineralized water, with connectors 59222201880003 Connection cable 1m for condensate drain with connection piece " |
0 | 0 | 0 | 2008 | 58226089060010 | |
25 | Corrosion | SaltEvent SC 500 - | 500 | 0 | SaltEvent | 2021 | 59226230910010 | |
26 | Climate | ClimeEvent C/1000/70a/5 "64609904 mobilde desgin 64624915 Door with window" |
1000 | -70 | 5 | 2020 | 6348842 | |
27 | Temperatur | LabEvent T/210/40/3/M "64609903 Access port ø 125 mm Position L5 58562442310080 Door contact switch for customer connection" |
210 | -40 | 3 | 2018 | 58566244410010 | |
28 | Temperatur | LabEvent T/210/40/3/M "64609903 Access port ø 125 mm Position L5 58562442310080 Door contact switch for customer connection" |
210 | -40 | 3 | 2018 | 58566248160010 | |
29 | Stability | PharmaEvent C/600 - | 600 | 0 | PharmaEvent | 2021 | 56746062150010 | |
30 | Stability | PharmaEvent C/600 - | 600 | 0 | PharmaEvent | 2021 | 56746062150020 | |
31 | Stability | PharmaEvent C/1300 - | 1300 | 0 | PharmaEvent | 2021 | 56746062190030 | |
32 | Stability | PharmaEvent C/1300 - | 1300 | 0 | PharmaEvent | 2021 | 56746062190040 | |
33 | Climate | ClimeEvent C/340/70a/5 "64624915 Door with window 64609904 mobile design" |
340 | -70 | 5 | 2021 | 6352146 | |
34 | Schock | VT³ 7012 S2 "64624983 Interface RS 232 64625918 Refrigerant R449A instead of R404A" |
120 | -80 | ShockEvent | 2018 | 58566240130010 | |
35 | Climate | ClimeEvent C/600/70a/5 "64611904 mobilde desgin 64624915 Door with window" |
600 | -70 | 5 | 2021 | 6353971 | |
36 | Climate | ClimeEvent C/340/70a/5 "64624915 Door with window 64609904 mobile design" |
340 | -70 | 5 | 2021 | 6352147 | |
37 | Temperature | LabEvent T/210/70/5 "64624931 Temperature measurement on test specimen switchable by reversible control sensor " | 210 | -70 | 5 | 2018 | 58566245980010 | |
38 | Climate | ClimeEvent C/600/70a/5 "64611904 mobilde desgin 64624915 Door with window" |
600 | -70 | 5 | 2021 | 6356280 | |
39 | Climate | ClimeEvent C/180/70a/5 "64624915 Door with window 64609904 mobile design" |
180 | -70 | 5 | 2021 | 656117 | |
40 | Climate | ClimeEvent C/600/70a/5 "64611904 mobilde desgin 64624915 Door with window" |
600 | -70 | 5 | 2021 | 6356277 | |
41 | Climate | ClimeEvent C/340/40/5 "64624915 Door with window 64609904 mobile design" |
340 | -40 | 5 | 2021 | 6356314 | |
42 | Climate | ClimeEvent C/600/70a/5 "64611904 mobilde desgin 64624915 Door with window" |
600 | -70 | 5 | 2021 | 6356278 | |
43 | Schock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2021 | 6357903 | |
44 | Schock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2021 | 6357904 | |
45 | Climate | ClimeEvent C/1000/70a/3 "64612904 mobile design 64624915 Door with window" |
1000 | -70 | 3 | 2021 | 6356320 | |
46 | Stability | PharmaEvent C/1300 - | 1300 | 0 | PharmaEvent | 2021 | 56746062680010 | |
47 | Schock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2021 | 6357906 | |
48 | Schock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2021 | 6357908 | |
49 | Schock | ShockEvent T/120/V2 - | 120 | -80 | ShockEvent | 2021 | 6357909 | |
50 | Climate | LabEvent L C/64/70/3 (Table Stock) - | 64 | -70 | 3 | 2021 | "LabStk017 68059019 562041724" | |
51 | Climate | LabEvent L C/64/40/3 (Table Stock) - | 64 | -40 | 3 | 2021 | "LabStk018 68059018 562042056" | |
52 | Climate | LabEvent L C/64/70/3 (Table Stock) - | 64 | -70 | 3 | 2021 | "LabStk019 68059019 562042059" | |
53 | Climate | LabEvent L C/100/40/5 (Table Stock) - | 100 | -40 | 5 | 2021 | "LabStk020 68059013 562042064" | |
54 | Climate | ClimeEvent C/600/40/3 "64611904 mobilde desgin 64624915 Door with window" |
600 | -40 | 3 | 2021 | 6356315 | |
55 | Climate | ClimeEvent C/600/70a/3 "64611904 mobilde desgin 64624915 Door with window" |
600 | -70 | 3 | 2021 | 6356319 | |
56 | Temperature | LabEvent T/110/70/3 64845907 Door with window | 110 | -70 | 3 | 2021 | 6357891 | |
57 | Climate | ClimeEvent C/340/40/3 "64242915 Window in the door 64609904 mobile design" |
340 | -40 | 3 | 2021 | 6356308 | |
58 | Climate | ClimeEvent C/340/70a/5 "64624915 Door with window 64609904 mobile design" |
340 | -70 | 5 | 2021 | 6356321 |
*Subject to prior sale. While stock last.